COLIFORM
ISOLATION TRANSWAB®
For the early detection of E. coli in the environment
Escherichia coli
and Coliforms are traditionally used as indicator organisms for
fecal contamination in water and other environmental samples.
Detection of these organisms usually points to poor hygiene at some
stage in the production process or pollution of water at the source.
Based on a
traditional test for Coliforms, the
Coliform Isolation Transwab®
provides a simple method for detecting these organisms—showing a
definite color change from purple to yellow when Coliforms are
present.
INSTRUCTIONS FOR
USE
1. Peel
back wrap to expose both caps
2. Remove
swab and sample test site
3. Remove
cap of culture tube with thumb and forefinger and discard
4. Insert
swab in culture tube and push down fully to immerse swab
completely
5. Fill
time, date, and site details
6. Incubate
37° C for 18-24 hours
7. Read
results. A positive result is indicated by a color change from
purple to yellow.
A negative result will show no color change
8. Record
results and dispose of tube
PRECAUTIONS WHEN
SWABBING
1. When
sampling an area always use the same swabbing technique
2. Always
try to sample the same surface area (100cm² or 200cm²), be
consistent in your sampling
3. The
moisture level on the surface should not vary at different sample
times. It may be preferable with dry surfaces to wet the swab in a
suitable wetting agent such as Ringes, Tween Lecithin or Tween
Peptone Water
COMPETITIVE
COMPARISON SHEET
RODAC PLATES/CONTACT SLIDES (VRBA or VRBGA)
COLIFORM TRANSWAB®
1 Six
months shelf-life or less
1 year shelf-life
2 Refrigerated
Storage Room Temperature Storage
3 Reading
results time consuming & misinterpretations Simple Color Change Indicating Result
4 Wet
surfaces can cause swarming on plates & unreadable Wet surfaces do not effect
and
& can even
enhance
5 Rough
uneven surface can not sampled properly Rough or uneven surfaces do not
affect
sampling
APPLICATIONS
FISHING INDUSTRY,
MEAT INDUSTRY, DAIRY INDUSTRY, POULTRY INDUSTRY, PROCESSED
FOODS
SHELF-LIFE
The expiry
date is 12 months from the month of manufacture and is printed on
the tube label, Peel Pouch and outer box
STORAGE
Coliform
Isolation Transwab® should be stored in a dry area between +5° C to
+25° C. DO NOT FREEZE
STERILIZATION
method is by irradiation
REFERENCES
1. Ref
Number: 000262
Murphy F. Tanker Hygiene Control 1993.
Key Words: MW%)#; MW504; MWE: E. coli; Coliform
2. Ref
Number 00392
Lockett,
c. An In-House comparative study of MW503 Coliform Isolation
Transwab and
MW504 Hygiene Test at
two incubation temperatures. 1984
© Lakewood
Biochemical Co., Inc. Dallas, TX 75214 |
|